The general purpose controller has a graphic display with four 4-20 mA transmitter input channels and 6 programmable relays. Select from one of three run mode configurations including 1) Multi-tank with 4 inputs and 4 relays; or 2) Pump control with 1 input and 6 relays for lift stations including duplexing; or 3) Differential level with 2 inputs and 4 relays for municipal screen or rake control. Each relay can be configured on a single set point or latched on two set points for automatic fill or empty control. The LCD displays engineering units, relay and span status for each channel. The MicroSD card is ideal for data-logging storage and retrieval.
Graphic tank display for better process and machine ...
(3) The general purpose controller is offered in three versions with 1 or 2 relays and 1-3 sensor inputs. The LC40 provides a high or low level switch with a single sensor input. The LC41 provides latched automatic fill or empty control with two sensor inputs. The LC42 provides latched automatic fill or empty control and an independent high or low level switch with three sensor inputs. Package the controller with any of our level switches.
LED indicators provide user with power, sensor and relay status
Fail-safe relay control of pumps and valves with 0-60 second time delay
(6) The general purpose panel meter provides single tank level indication with optional 2 or 4 relays, 4 or 8 set points and an isolated analog repeater. Each relay can be configured on a single set point switch or latched on two set points for automatic fill or empty control. Package the meter with any of our level transmitters.
Application The general purpose meter displays engineering units with one 4-20 mA or 0-10 VDC transmitter input channel and is offered in three configurations with optional 2 or 4 relays, 4 or 8 set points and an isolated 4-20 mA repeater. Each relay can be configured on a single set point or latched on two set points for automatic fill or empty control including duplexing. For field mount installations, order the single or two meter NEMA box.
Bright 6-digit LED main display and secondary unit display with relay status indicators
1/8 DIN enclosure with NEMA 4X faceplate and shallow depth case
32-point linearization function for volumetric tank measurement
(2) Factory calibrated, the general purpose indicator reads 0-100% of span with two or four level transmitter input channels. A single push button allows users to scroll through their active channels. With the optional MicroCal PC calibration kit, users can customize engineering units, configure FET alarm set points from level transmitter and switch inputs, and/or linearize the volumetric measurement of odd shaped tanks. Select the 2 channel for loop insertion with PLC's and the 4 channel for stand alone indication.
Display type: LCD, 5-digit
Display units: Factory cal: % of span PC cal: engineering
(6) The general purpose two-wire ultrasonic transmitter provides non-contact level measurement up to 32'-8" or 12.2m, and is ideally suited for challenging corrosive, coating or waste liquids. The transmitter is broadly selected for atmospheric bulk storage, day tank, process vessel and waste sump applications. Media examples include ink and polymer.
Accuracy: ± 0.15% of span in air
Resolution: 0.125" (3 mm)
LED indication: Power, calibration and diagnostics
(4) The general purpose two-wire ultrasonic transmitter provides non-contact level measurement up to 4' or 1.2m, and is ideally suited for challenging ultrapure, corrosive, slurry or waste liquids. The transmitter is typically selected for small atmospheric process vessel, IBC tote, 55gallon drum and waste sump applications. Media examples include chromic acid and copper sulfate.
Provides non-contact level measurement up to 32' or 10m, and is ideally suited for challenging ultrapure, corrosive or waste liquids. Push button calibrated, the transmitter is broadly selected for atmospheric bulk storage, day tank and waste sump applications. Media examples include wastewater and sodium hydroxide.
The general purpose ultrasonic switch and controller provides non-contact level detection up to 24.6' (7.5 m) with 3 SPDT 60 VA 1A relays. EchoSwitch II features an LCD display with digital push button configuration. Each relay can be configured on a single set point alarm or latched on two set points for automatic fill or empty in simplex, duplex or triplex control modes with integral timer delay. The switch is well suited for a broad range of corrosive, waste and slurry type media. EchoSwitch II is broadly selected for atmospheric day tank, pump lift station and sump applications. Automation The integral three channel controller has powerful automation features including advanced pump and alarm control logic designed for day tank, ...
(16) The general purpose ultrasonic switch provides non-contact level detection up to 26.2 ft. or 8m with 3 relays and 1 - 6 set points. Each relay can be configured on a single set point alarm, two latched set points for automatic fill or empty control or two independent set points for out of bounds alarming and alternating relays 1 and 2 full duplex.
Resolution: 0.125"
Repeatability: 0.25"
Hysterysis: Adjustable over range
LED indication: Power, relay and echo status
Calibration: Target, push button
Memory: Non-volatile
Contact fail-safety: Reverts to de-energized state during echo-loss
The general purpose, DL10 ultrasonic sensor provides non-contact level measurement up to 49.2" (1.25m) with a 4-20 mA output. The DL10 directly replaces contact measurement sensors connected to a PLC analog input card for easy design conversion or field retrofit. The two-wire, 4-20 mA output is ideal for longer signal distances up to 1000'. The sensor is well suited for a wide range of corrosive, sticky or dirty type media. The DL10 is broadly selected for small atmospheric tank, IBC, drum, skid or process vessel and sump applications. To configure EchoPod, download our free WebCal software and purchase one USB interface tool. Features Transmitter provides 4-20 mA level measurement Compact sensor with 2" beam width and 2" dead band ...
The general purpose, ultrasonic sensor provides non-contact level detection up to 49.2" (1.25m) with 4 SPST 60 VA 1A relays. The DS14 directly replaces contact switches connected to a PLC with 1-4 discrete points for easy design conversion or field retrofit. Each relay can be configured on a single set point alarm or latched on two sets for automatic fill or empty in simplex or duplex control modes with fail-safe logic. The embedded controller can replace external control hardware. The sensor is well suited for a wide range of corrosive, sticky or dirty type media. The DS14 is broadly selected for small atmospheric tank, IBC, drum, skid or process vessel, lift station and sump applications. To configure EchoPod, download our free WebCal ...
(4) The general purpose nonintrusive capacitance level switch is a great choice for clean or ultrapure, aqueous based liquids with non-coating and/or scaling characteristics. Media examples include deionized
water and hydrochloric acid. The IA relay provides a reliable switch interface with remote devices such as a PLC, SCADA or alarm.
Level detection through plastic tank walls up to 1" thick
Sensor mounting brackets are offered in common tank materials for adhesive or tack-weld install.
Tank mounting: Non-intrusive Tank mat. comp.: non-metallic
(8) The general purpose optic switch is an excellent choice for leak detection in and around secondary containment sumps, tanks and pipes. The sensor can be applied in a broad range of chemical solutions. Media examples include ferric chloride and chlorine. The IA relay provides a reliable switch interface with remote devices such as a PLC, SCADA or alarm. The submersible sensor is universally mounted within the interstitial space of the vessel.
(6) The general purpose vibration level switch is an ideal choice for more challenging liquids including those with light to medium coating, scaling or foaming characteristics. Media examples include wastewater and diluted caustic. The IA relay provides a reliable switch interface with remote devices such as a PLC, SCADA or alarm. The submersible sensor is universally mounted through the wall or inside the tank.
Rugged PP-Ryton sensor and cable rated NEMA 6X or IP68
IA relay selectable NO or NC via power supply wiring polarity
Compatible with Flowline alarm, controller and fitting accessories
Not effected by process foam or light to medium build-up
(24) CSA and Cenelec approved intrinsically safe for use in hazardous area locations, the ultrasonic level switch is broadly applied in chemical, solvent, hydrocarbon and petroleum based liquids. Media examples include jet fuel and sulfuric acid. The IA relay provides a reliable switch interface with remote devices such as a PLC, SCADA or alarm.
PP or PFA Teflon sensor and cable rated NEMA 6X or IP68
A relay selectable NO or NC via power supply wiring polarity
CSA and Cenelec approved intrinsically safe for use in hazardous area locations